文章
  • 文章
Search
Home >> News >>Company >>Industry information >> Instructions for use of disposable virus sampling tube
Details

Instructions for use of disposable virus sampling tube

This standard specifies the technical requirements for disposable virus sampling tubes and the corresponding test methods and inspection rules.


This standard is applicable to disposable virus sampling tube products


2 normative documents


The provisions in the following documents become the provisions of this standard through reference in this standard. For dated references, all subsequent amendments (excluding Corrigendum) or revisions are not applicable to this standard. However, parties to agreements based on this standard are encouraged to study whether the new versions of these documents can be used. For undated references, the latest edition is applicable to this standard.


GB / T 1. 1 guidelines for standardization Part 1: structure and compilation of standards


GB 20001.10 Standard Compilation Rules Part 10: product standards


GB 191 packaging, storage and transportation diagram.


GB / T 2828.1 sampling inspection procedures by attributes - Part 1: sampling plans for batch inspection retrieved by acceptance quality limit (AQI).


3 Classification


3.1.1 model: b90-1, b90-3, b90-6, b130-1, b130-3, b130-6, b160-1, b160-3, b160-6


3.1.2 specification: IML, 2M1, 3M1, 6m1 (preservation tube 75mm, 100mm, 130mm)


4 technical requirements


4.1 appearance requirements


-The virus sampling tube shall be used for secondary preservation. The appearance of the tube shall be uniform, transparent, bright and clean as a whole, free of oil and bubbles: the preservation solution shall be colorless, transparent or light red, and shall not have particles or impurities.


4.2 pH requirements of preservation solution


The pH standard range of preservation solution is required to be 7. ± 0.5


4.3 storage liquid volume requirements


According to different liters, the volume of preservation solution shall be 1mi, 2mi, 3MI and 6m1, and the error shall be less than 110%


4.4 tightness


When the cap of the storage tube is tightened, there shall be no leakage of storage solution.


5 inspection method


5.1 appearance inspection


Under natural light, through visual inspection and hand feeling, the results shall meet the requirements of 4.1.


5.2 pH detection of preservation solution


Take out the preservation solution, measure the pH value with the pH meter for 3 times at 25 ° C, and take the average value, which shall meet the requirements of 4.2.


5.3 detection of storage solution


Put the test tube with preservation solution on the electronic balance, weigh it and record M1: then suck out all the liquid in the test tube and weigh it as m2. The staining of m1-m2 shall meet the requirements of 4.3.


5.4 tightness test


After sealing the preservation portion with preservation solution, turn it upside down for 6h to see if there is liquid exudation, which shall meet the requirements of 4.4.


6 storage


The products shall be stored at 2-35 ° C in a non corrosive gas and well ventilated warehouse with a shelf life of 1 year.


7 transportation


The products shall be loaded and unloaded with care during transportation to avoid product damage caused by extrusion. It is forbidden to put them upside down during stacking


8 sampling scheme


Five samples are randomly sampled from each batch for sampling inspection.


Conclusion: all items meet the technical requirements and the products are judged as qualified.


The above is what Xiaobian introduced to you. There is a user manual for disposable virus sampling tube. Please check all the contents of!!. If you are still interested in relevant contents, please continue to pay attention


The above is all the contents of the instructions for the use of disposable virus sampling tube introduced by Xiaobian. If you are still interested in relevant contents, please continue to pay attention to Cangzhou Fukang Pharmaceutical Products Co., Ltd


seo seo